MDA 8038HD
電機驅動分析儀建立在一個 8 通道上, 12-bit 解析度示波器平臺。 它採集任何信號並執行三相電力和機械功率計算。 它提供完整的電源部分和嵌入式控制測試範圍。
Bandwith 350 MHz Input Channels 8 Max Sampling Rate 10 GS/s Resolution 12-bit Memory 50 Mpts - 5 Gpts Max Memory 5 Gpts - Static power analysis - like a dedicated power analyzer
- Dynamic power analysis – capture more information
- Complete test coverage – control system, power section, motor
- Comprehensive mechanical interface
- Harmonics calculation option
- Vector display option (THREEPHASEVECTOR)
- Waveform Transformations option (THREEPHASEdq0)
- 16 Channels with OscilloSYNC™
The mean-value Numerics table displays voltage, current, power, speed, torque, etc. values for short (or long) time periods during constant load, speed and torque operating conditions - just like what a dedicated power analyzer instrument provides.
Capture thousands of power cycles over long time periods. Per-cycle Waveform views help you understand dynamic behaviors. Use Zoom+Gate to isolate and correlate power behaviors to control system operation during dynamic load, speed, and torque operating conditions.
Acquire and display analog, digital and serial data signals from both power and embedded control systems. Correlate power system behaviors to control system activity during time periods as short as a single device switching cycle.
Nine speed, four angle, and five torque sensors supported – most supported only by the Motor Drive Analyzer. Calculate mechanical power at your bench without external sensors connected.
Rigorous software DFT method precisely separates desired frequency content. Provides THD numeric calculation and per-cycle Waveforms, harmonic order table and spectral displays (up to nine simultaneous).
Two simultaneous vector displays permit visualization of three-phase system voltage and current. Vector information can be harmonically filtered and is compatible with Zoom+Gate to show vector changes during dynamic or long acquisitions.
Support for two simultaneous αβγ (Clarke) and dq0 (Park) real-time transformations with X-Y plot capability available for d vs. q and α vs. β components
View and control 16 analog channels on a single display with OscilloSYNC Oscilloscope Synchronization. Setup is incredibly easy – it’s like having a single 16-channel acquisition system with the benefit of being able to use each oscilloscope or MDA independently.